Click to go back to Turf Watch
SENSORS:
Wind Speed
| Accuracy: Range: Gust survival: |
±.66 mph (0.3 m/s) 0 - 134 mph (60 m/s) 220 mph (100 m/s) |
Wind Direction
| Accuracy: Range: Gust survival: |
± 3° 1 - 360° 220 mph (100 m/s) |
Solar Radiation
| Sensitivity: Accuracy: Sensor: |
Typically 80 m A/1000
W/m2 ±3%, maximum of 5% Silicon Photovoltaic Detector, High Stability Cosine corrected to 80° angle of incidence |
Air Temperature
| Range: Accuracy: |
-50° to 140° F, (-50° to 60° C) ±0.54° F, (0.3° C) |
|
| Platinum RTD probe | ||
Relative Humidity
| Range: Accuracy at 68° F: Sensor: Stability: |
0 - 100% RH ±2% at 0 - 90% RH ±3% at 90 - 100% RH Silicon Photovoltaic Detector, High Stability Cosine corrected to 80° angle of incidence Better than ±2% RH, 2 years |
Rain Gauge
| Bucket Size: Sensitivity: Sensor: Stability: |
6.04" diameter (15.34 cm) 1 tip per 0.01" Silicon Photovoltaic Detector, High Stability Cosine corrected to 80° angle of incidence Better than ±2% RH, 2 years |
Barometric Pressure
| Accuracy: Resolution: |
±1.35 mb or ±.04 in Hg Infinite |
STATION:
| Temperature: Wind
Threshold: Instrumentation: Electrical: Other: |
-40° to +150° F (-40° to 65° C) 110 mph
constant Mounted 3 meters above ground Battery back-up with continuous data capture |
|
Additional information available upon request |
||
Copyright © 2004 Weather Metrics, Inc. All Rights Reserved. Contact us.
|